Ships Canada-wide from our Quebec warehouse

Enerwav

Size before you buy

Size your system before you spend a dollar.

The model combines site inputs with NRCan annual resource data. A site study must confirm roof, electrical, and utility conditions.

Start with the job

Choose a reference case.

Enter your measured values. No load profile is assumed.

Residential modeSwitch to commercial

01 / Inputs

Define the home

Reviewed NRCan annual PV potential, south-facing at latitude tilt.
Context only. This choice does not silently alter the capacity calculation.
Information for the brief only. Financing costs and contract pricing are not modelled.
kWh/year
Use one complete year, or leave blank and enter all 12 monthly values below.
Enter 12 monthly electricity-use values instead
kWh
kWh
kWh
kWh
kWh
kWh
kWh
kWh
kWh
kWh
kWh
kWh
m²
Optional. Enter area after known setbacks and obstructions.
kWdc
Optional. The model uses the lowest stated capacity bound.
CAD/kWh
User-entered import energy value. Enerwav does not insert a province default.
Export and rate contextUse this only when no energy is expected to export. Otherwise enter both export inputs.
%
Enter only with an explicit export credit.
CAD/kWh
Leave blank to keep export value suppressed.
Installed cost and operating assumptions
CAD/Wdc
User-entered lower or single installed-cost assumption.
CAD/Wdc
Optional. Blank uses the entered installed cost as both boundaries.
CAD
Alternative to CAD/Wdc. Do not enter both cost methods.
CAD
Optional upper total-cost boundary.
CAD/year
Required for discounted cash flow. No universal O&M default is applied.
CAD/year
Optional upper O&M boundary.
The screening view is fixed at 25 years. Financing structure is informational.
%
Visible user assumption. No hidden discount rate is applied.
%/year
Visible user assumption. Enter zero to hold value flat.
%/year
Editable preliminary NREL-derived assumption. It is not a guarantee.
Storage upper-bound screen
Presets set nameplate values only. They do not create annual savings.
kW
Nameplate discharge power.
kWh
Nameplate energy.
%
Visible editable efficiency convention.
hours
Duration used for the energy-limited clipping bound.
kW
Optional target limit.
kW
Optional observed peak limit.
CAD/kW-month
User-entered tariff demand charge.
months
Whole number from 1 to 12.
CAD/kWh
Entered cost of charging energy.
CAD/kWh
Entered value of discharged energy.
cycles/year
Annualization remains withheld without the confirmations below.

Corporate ITC and CCA are not shown in residential mode.

Choose a mode and enter site information to begin.